Index |
Type |
Description |
Solution |
W6/101 |
Warning |
Punching shear resistance at the column perimeter (vRd,max) is not sufficient acc. to §6.4.3(2). |
Use higher grade of material or increase thickness of the plate. |
W6/F102 |
Warning |
Punching shear resistance at the basic control perimeter (vRd,c) is not sufficient acc. to §Re 6.4.3. Punching shear reinforcement is required. |
To avoid design of shear reinforcement try to increase amount of longitudinal reinforcement. |
W6/110 |
Warning |
Area of a single link of shear reinforcement is less than minimum value acc. to §9.4.3(2). |
|
W6/111 |
Warning |
Tangential spacing of shear links (st,u1) of the outermost perimeter of shear reinforcement inside the basic control perimeter (u1) exceeds maximum value acc. to §9.4.3(1). |
|
W6/112 |
Warning |
Tangential spacing of shear links (st,out) of the outermost perimeter of shear reinforcement outside the basic control perimeter (u1) exceeds maximum value acc. to §9.4.3(1). |
|
W6/113 |
Warning |
Last perimeter of shear reinforcement is placed at a distance greater than (kd) from the outer control perimeter uout, see §6.4.5(4).
|
|
W6/114 |
Warning |
Number of perimeters of shear reinforcement is less than the minimum value acc. to §9.4.3(1). |
|
W6/115 |
Warning |
Radial spacing sr of shear reinforcement perimeters around the column exceeds the maximum value acc. to §9.4.3(1). |
Change assumptions for design of shear reinforcement (by using Design defaults). |
W6/116 |
Warning |
Distance s0of first perimeter of shear reinforcement from the column face is not within the interval acc. to §9.4.3(1) and (4). |
W6/F117 |
Warning |
Punching resistance of plate with designed shear reinforcement vRd,cs is not sufficient acc. to §Re 6.4.5. |
Use higher grade of material or increase thickness of the plate. |
W6/118 |
Warning |
A control perimeter ui outside the basic control area is not generated with same shape as the basic control perimeter u1, see §6.4.2(7). |
|
W6/119 |
Warning |
Node cannot be calculated for punching. The basic control perimeter is detected as type of straight line between opposite edges of the plate so different failure mode is assumed. |
|
W6/120 |
Warning |
Design of punching shear reinforcement cannot be done. The outer control perimeter uout is not found correctly.
|
|
W6/121 |
Warning |
Node cannot be calculated for punching. A point force is applied on the node. |
Remove the point force and apply the load through a column (1D member). |
W6/122 |
Warning |
Node cannot be calculated for punching. Connected plate is not horizontal.
|
|
W6/123 |
Warning |
Node cannot be calculated for punching. Connected column is not perpendicular to the plate. |
|
W6/124 |
Warning |
Node cannot be calculated for punching. Connected column goes through the plate. |
Split the column in the node to get separate column above and below the plate. |
W6/127 |
Warning |
Node cannot be calculated for punching. Connected column is rotated by alpha angle. |
Rotate the column through a rotation of its LCS instead of alpha angle (if possible). |
W6/128 |
Warning |
Node cannot be calculated for punching. Connected column is not prismatic.
|
|
W6/129 |
Warning |
Node cannot be calculated for punching. Connected columns above and below the plate have different orientation of LCS. |
Unify orientation of LCS of both columns (if possible). |
W6/130 |
Warning |
Node cannot be calculated for punching. The nodal support is not perpendicular to plate by its z-axis. |
|
W6/131 |
Warning |
Node cannot be calculated for punching. Connected column has not supported type of cross-section. |
|
W6/132 |
Warning |
Node cannot be calculated for punching. Connected plate is identified as foundation but this is not valid everywhere around the node. |
|
W6/133 |
Warning |
Node cannot be calculated for punching. Combination of nodal support and linked 1D member is not allowed. |
|
W6/134 |
Warning |
Node cannot be calculated for punching. Subregion near the node is not from the concrete material. |
|
W6/136 |
Warning |
Node cannot be calculated for punching. An opening with unsupported shape is detected around the node. |
Simplify shape of the opening to be rectangle or circle (if possible) |
W6/137 |
Warning |
Reduced length of the basic control perimeter due to openings is significant. The simplified method for the Beta factor is not recommended to use. |
Change the method for determination of the Beta factor in the Concrete settings. |