Response spectrum generator according to CSN (Czech standard)
Procedure to input a new CSN seismic spectrum
- Expand branch Libraries of the main tree menu.
- Expand sub-branch Loads.
- Start function Seismic spectrum to open the Seismic Spectrum Manager.
- Click button .
- In combo box Input type select option CSN - Czech standard.
- Review and, if required, adjust the spectrum parameters.
- Click button to review or modify the code-defined parameters of the spectrum.
- Confirm the code parameters with .
- Click to confirm the spectrum.
- Close the Seismic Spectrum Manager.
Spectrum definition and code parameters
A response spectrum can be defined according to CSN by selecting CSN - Czech standard as Input type.
Max frequency & Step
The values of the spectrum are generated between a maximum period of 4 seconds (=0.25 Hz) and the input maximum frequency, using the input Step value.
Code parameters
This button opens the dialogue defining the code-dependent parameters.
coeff. accel. ag
Value of the design acceleration expressed as a multiple of the acceleration of gravity g
Ag - nominal acceleration
Nominal ground acceleration
n - Eta (damping coefficient)
Damping correction coefficient
E - Xi (relative damping coefficient)
Relative damping coefficient, given in % (typical value is 5%)
Tb, Tc, Td, S, Beta, k1, k2 manually?
When this setting is No, the values Tb, Tc, Td, beta0, k1, k2, S are calculated
When this setting is Yes, the values Tb, Tc, Td, beta0, k1, k2, S are input manually
Subsoil type
Ground type (A, B, C)
Tb
Lower limit of the period of the constant spectral acceleration branch
Tc
Upper limit of the period of the constant spectral acceleration branch
Td
Value defining the beginning of the constant displacement response range of the spectrum
k1
Exponent for the TC-TD branch
k2
Exponent for the long period branch (T>TD)
S - soil factor
Soil factor
beta0
Amplification factor for type A subsoil
Theoretical background
The seismic spectrum is defined as
The damping correction factor is calculated as
The values S, Tb, Tc, Td are defined according to the subsoil type (unless defined manually)
Subsoil type | S [-] | TB [s] | TC [s] | TD [s] |
A | 1.0 | 0.10 | 0.4 | 3.0 |
B | 1.0 | 0.15 | 0.6 | 3.0 |
C | 0.9 | 0.20 | 0.8 | 3.0 |
The values k1, k2 and beta0 are set by default (unless defined manually)
Although the formulation slightly differs, with the default values of k1, k2 and beta0, the definition of the spectrum is exactly the same as the elastic response spectrum of the EN1998-1:2004