Parameters of a non-linear support
Parameters of a nonlinear support can be divided into two groups:
Non-linear function manager
Non-linear function that specifies the behaviour of a non-linear support can be defined in a standard SCIA Engineer database manager.
The function itself consists of a positive and negative branch. The function must always pass the zero point, i.e. the zero displacement must correspond to zero force. Any "switchbacks" in the diagram are not allowed. This means that e.g. the positive branch may rise or keep a constant force value but it is not possible to let the force go down with increasing displacement.
In addition to the function itself, there is a special parameter for the positive and negative axis. Possible values of this parameter are
Rigid |
If ON, the support is considered infinitely rigid once the limit displacement (the last input displacement value defined in the diagram) is reached. |
Free |
If ON, the support is considered free once the limit displacement (the last input displacement value defined in the diagram) is reached. |
Flexible |
If ON, the stiffness of the support is considered constant once the limit displacement (the last input displacement value defined in the diagram) is reached. The force value specified for the last input displacement is used. |