Required parameters for Soil-in calculation

What all must be defined:

Soil-in settings in the Solver setup

Soil combination:

linear combination which is used for the soil-in calculation.
Even though it is not an exact solution, for practical reasons the C parameters are not calculated separately for each load case or each load case combination. The user must specify one particular reference combination that is used to calculate the C parameters. The calculated C parameters are then applied in all remaining defined load cases and combinations.

Maximum soil interaction iteraction

number of iteration cycles (when the program stops iterations if there are still no proper C parameter calculated, in case that results diverge), the max. limit is 99 steps

C1x:

the parameter defined by the user

C1y:

the parameter defined by the user

C1z:

initial value for soil-in (if the support type is Soilin)

C2x:

initial value for soil-in (if the support type is Soilin)

C2y:

initial value for soil-in (if the support type is Soilin)

Thickness of loose layer at contact level [m]:

setting in solver settings for automatic definition of loose layer at contact stress level for better handling of foundation at great depth and faster convergence of soilin iterations. This layer is automatically created and managed by soilin to handle the fact, that a thin layer of soil is always somewhat damaged and loose, just at the contact level. This item is set 0 as default. User can choose this layer 0 - 10m.

On the background new layer in borehole under the slab is created with thickness from this parameter and other parameters according layer in this possition from borehole but parameter 'm' is set as 0.

Modify Soilin stiffness parameters for seismic analysis: "Modify Soilin stiffness parameters for seismic analysis"

parameters of soil-in in seismic spectral analysis are modified for modal analysis by coef.

Coefficient for horizontal stiffnesses:

coefficient for horizontal components of stiffness support

Coefficient for vertical stiffness:

coefficient for vertical components of stiffness support

 

The source of not calculated parameters depends on the support type. It is described in the previous chapter.